Assessment of kVp accuracy and reproducibility of X-ray machines as a quality control measure in selected hospitals in Abuja, Nigeria

Abstract

Background: The accuracy and reproducibility of the tube potential (kVp) affect image contrast, patient dose and repeat examinations. Published kVp quality control data from Abuja, Nigeria, are limited. Objective: To evaluate kVp accuracy and reproducibility in X-ray units in selected hospitals in Abuja, Federal Capital Territory. Methods: In this cross-sectional study, five X-ray units (XM-1 to XM-5) in five hospitals authorised by the Nigerian Nuclear Regulatory Authority were tested using a Cobia Smart R/F solid-state kVp meter. Accuracy was measured at 60, 70, 80, 90, and 100 kVp at 20 mAs and expressed as the percentage deviation from the set value. Reproducibility was assessed from five readings at 70 kVp across mAs stations of 16–40 mAs and expressed as the coefficient of variation (CoV). The accuracy tolerance was ±5% at each setting, based on American Association of Physicists in Medicine (AAPM) and International Atomic Energy Agency (IAEA) standards. Results: The mean absolute kVp errors were 1.83%, 2.03%, 3.20%, 1.29%, and 2.40% for XM-1 to XM-5. Twenty-four of 25 measurements (96%) were within ±5%; the exception was XM-3 at 60 kVp (−6.25%). Measured kVp was below the set value in 23 of 25 measurements (mean deviation −1.92%). The CoV was 0.35%, 0.33%, 1.21%, 0.09%, and 0.05%, all within the limit. Four units met the criteria at every setting. Conclusion: Four of five units were compliant, and one (XM-3) needs recalibration. Measured kVp was slightly below the set value in most measurements. Routine per-setting kVp testing, including after repairs, is recommended, and larger studies that include unregulated facilities are needed.

Full text

The complete manuscript — including methods, results, discussion and references — is published as a PDF.

Download full paper (PDF)

Citation

Nwokorie Emaanual.C, Ogwuche, J.A., Auwal Abubakar, Okpaleke, S Micheal., Umar, Muhammed Sani, Dlama, Zira Joseph, Abba Mohammed. Assessment of kVp accuracy and reproducibility of X-ray machines as a quality control measure in selected hospitals in Abuja, Nigeria. Nigerian Journal of Medical Imaging and Radiation Therapy, Vol. 15, pp. 7. 2026. https://doi.org/https://doi.org/10.68947/njmirt-NVZT4905

Continue reading

Related articles

01
Journal article 17

Assessment of Knowledge and Attitudes of Radiographers towards Postgraduate Education in Radiotherapy in Kano, Katsina and Jigawa States of Nigeria

Zaharaddeen Usman Abubakar, Shakirah G. AbdulAzeez, Ibrahim Bashir Umar

ABSTRACT Background: Postgraduate programs in radiography commenced in Nigeria almost two decades ago. However, there is a paucity of radiographers with postgraduate qualifications in radiation therapy. There is a need...

Nov 19, 2026 20:26
Read article PDF